Fabrika niska cena Jednoručni spo2 senzor Pedijatrijski senzor Kompatibilan sa Mindray Oxi MAX-P Medicinski kabeli i pribor
Opis
Fabrika niska cena Jednoručni spo2 senzor Pedijatrijski senzor Kompatibilan sa Mindray Oxi MAX-P Medicinski kabeli i pribor
OEM broj dijelova i kršćanske reference:
| Proizvođač | OEM deo # |
|---|---|
| Nellcorr | MAX-P , MAX-P-I |
| Draegers | MX50066 |
| GE Healthcare > Marquette | 70124022 |
| Mindray > Datascope | 0010-10-12203 |
| Sage | DP062X-09M |
| Stryker > Physio Control | 11996-000116 |
Kompatibilnost:
| Proizvođač | Model |
|---|---|
| Baxter | Explorer, Monarch |
| Biolight | M9500, Q Series, Q3, Q5, Q7 |
| Biosys | BPM-200, SENTRY |
| CAS Med | 511 |
| Nellcor | N-10, N-180, N-190, N-20, N-30, N-560, N-600, N-600x, N-65, N-85, NPB-190, NPB-195, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, PM100N, PM10N, Senzori koji imaju Nellcor OxiMax Tehnologiju i 9 pinova |
| Kriticar | 506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3 |
| DRE | ASM 5000, Waveline, Waveline Plus |
| Digičar | LW600 |
| Draegers | Infinity Delta, Infinity Delta XL, Infinity Kappa, Narkomed 6400 |
| Фудајда Денсхи | Dynascope DS-7100, LX-7230N |
| GE Healthcare > Critikon > Dinamap | B105, B125, Carescape B650, Carescape V100, Compact DINAMAP MPS, E-NSAT, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro Series V2, ProCare 200, ProCare 400, ProCare Auskulatorni 400 |
| GE Healthcare > Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, PDM Modul, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500 |
| Goldway | Vet 420A, Vet 600A |
| Covidiens | Capnostream 35 (PM35MN) |
| Midmark > Cardell | 9403, 9405, 9500 Serija, 9500HD, MAX-12 Duo HD |
| Mindray > Datascope | Accutorr Plus, BeneView T1, BeneVision N1, DPM5, DPM6, DPM7, Duo, Expert, Passport, Passport 12, Passport 2, Passport 8, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V-Series, ePM 10M, ePM 12M, iPM-9800 |
| Мортара | Surveyor S12/S19 |
| Omron > Colin | BP-S510, T105NXM |
| Hp | FM20, FM30, Heartstream XL, FAST-SpO2, MP2, MP70, MX450, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3 |
| Smiths Medical > BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Autocorr, Mini Torr, Mini Torr Plus |
| Spacelabs | Ultraview SL, Ultraview SL 2700 |
| Lifepak 12, Lifepak 15 | |
| 1500, 42NT0-E1 LXi, 52N00, 52N0P, 52NT1, 53N00, 53N0P, 53NT0, 53NTP, Sve, Atlas (Nellcor SpO2), Atlas 6200 Serija, Encore 202EL, Propaq 244, Propaq CS, Propaq LT, Spot Vital Signs 42NOB, Spot Vital Signs 42NTB-E1 |
1. Опис производа:
|
Kompatibilna marka |
Nellcor Oxi-max , OEM broj dijela: MAX-P |
||
|
Tip senzora |
Odrasli, Dečji, Bebina, Novorođenčad; Plava pena bez lepljivog sloja, 3M neotpremljiva lepljiva, 3M bela pena sa lepljivim slojem. |
||
|
Materijal kabela |
beli PVC jaket, 3.2mm prečnik |
Sensor Connector |
Plastični adapter sa zlatnim galvanizovanim šipkama |
|
LED |
660nm/905nm/940nm |
Fotodetektor |
4mm² / 8mm² (veličina) |
|
Dužina kabela |
0,9м |
Pakovanje |
1 komad u jednom zip torbi |
2. Tehnički parametri proizvoda:
|
LED |
Crvena |
660nm normalno |
|
Infra crveno |
880/905/940nm normalno |
|
|
Tekstualni opseg |
Saturacija kisika (%SpO2) |
0% do 100% |
|
Pulsna frekvencija (udm) |
30 do 245 |
|
|
Tačnost |
SpO2 |
±1%(90~100%) |
|
±2%(80~90%) |
||
|
±3%(ispod 70%) |
||
|
Pulsna frekvencija |
±2udm(30-250udm) |
|
|
Uslovi smeštanja i transporta |
-10℃~+40℃ |
|
|
Radna temperatura |
±5℃~+40℃ |
|
|
Влажност за радњу/складиштење/транспорта |
0%-80% |
|
|
Hiperbarski tlak |
86kPa-106kPa |
|
3. Caremed Slika proizvoda с :