Compatível com Draegers Vitalert 2000/ Vitalert 3000 Cabo de Paciente ECG de 4 vias Clipe IEC Cabo ECG/EKG para Monitoração de Pacientes
Descrição
Compatível com Draegers Vitalert 2000/ Vitalert 3000 cabo de paciente ECG de 4 eletrodos com clipe IEC Cabo ECG/EKG para monitoramento de pacientes
Compatibilidade:
| Fabricante | Modelo |
|---|---|
| AAMI | TODOS |
| ATL | 800, 800 Plus, 800Plus, Apogee, CX ATL Ultrassom, CX200, CX400, HDI 9/200, HDI 9/2000, Interspec Cardiologia XL, Mark IV, Mark VII, Ultramark 4/5/7/9 |
| Abbot | EX-50, Lifecare 5100, Lifecare 5200 |
| Avançado | PM-1000, PM-1000EX |
| American Optical | 26125, 33167, 5260, 5330, Pulsar 4 |
| Carewell | CPM-8000 |
| Conmed | 90347 |
| Contec | CMS 6000, CMS 6800, CMS 7000, CMS 8000, CMS 9000 |
| Nelcorr | C-LOCK, N-1000, N-200, N-250, NPB-3900, NPB-4000 |
| Criticar | 1100, 2200, 504US, 504USP, 506, 507, 507E, 507ELC2, 507S, 508, 602-4B, 602-4USP, 8100, 8100E, 8100EP, 8100EP1, Poet 2, Scholar, nCompass, nGenuity 8100E |
| Estilo DIN | TODOS |
| DRE | Waveline EZ MAX, Waveline Pro |
| Datex Ohmeda | enGuard CM5 |
| Digicare | LW600 |
| Dixtal | DX 2022, DX 2515 |
| Draegers > Air Shields | HRRM-71-1, HRRM-71-2, II, III, Porta-Fib I, Porta-Fib II, Porta-Fib III, System 5 (Novo), System 6 (Neonatal) |
| Draegers | Vitalert 2000, Vitalert 3000 |
| Edan | M50, M8, M80, M8A, M8B, M9, M9A |
| G.A. | 556 |
| GE Dinamap | série 8100T, Série 8700, 8700/9700, Série 9700, MPS Select, Pro 1000 |
| Goldway | G30, G40, UT4000A, UT4000Apro, UT4000B, UT4000C, UT4000F, UT4000F Pro, UT4800, UT6000A, UT6000F |
| Guthan | 1000 |
| Infiniums | Infitron II, Omni, Omni II |
| Interspec (Irex) (JandJ) | Cardiologia XL, Mark IV, Mark Vii, Ultramark 4, Ultramark 4 Plus, Ultramark 5, Ultramark 7, Ultramark 9 |
| Invivo | 101, 102, 200, 300, 360SL, 450SL, 521A, Escort 100, Escort 101, Escort 102, Escort 200, Escort 300, M12, Millennia 3500, PortaPak 1000, PortaPak 80, PortaPak 90, PortaPak 90/1000, Prism |
| Ivy Biomedical | 101, 101 (antes de 1989), 3000, 402, 405T, 700, 7600, 7800, Cardiac Trigger Monitor 3150 |
| LSI | 261, LS5 |
| Mediana | YM6000 |
| Midmark > Cardell | 9403V, Série 9405, Série 9500, MAX-12 Duo HD, Max-1 |
| Mindray > Datascope | DPM4, DPM5, MEC 1000, MEC 1200, MEC 200, MEC 2000, MEC-1200Vet, PM 7000, PM 8000, PM 9000 |
| Nihon Kohden | 7102A, BSM-7102A, BSM-7300A, BSM-8108A, BSM-8301A, BSM-8302A, BSM-8500A, BSM-8502A, BSM-8800A, Life Scope 12, Life Scope 6, Life Scope 7, Life Scope 8, Life Scope 9, MU-831RA, OEC-6102A (s/n>20156), OEC-6105A (s/n>20226), OEC-7102A, OEC-8108A, TEC 5531E, TEC-5200A (s/n>20421), TEC-7100A, TEC-7200A, TEC-7300A |
| Novametrix | 902, 903, 910, Life Defense 1 |
| Omron > Colin | BP-308, BP-408, CBM3000, M20, M30, MS20 |
| PPG | Guardian 1001, N1001 |
| PaceTech | 2100, 2200, 4000, 4100, MiniMax 4000CL, Minipack 300, Minipack 3000, Minipack 3000/3100, Minipack 3100, Modular/4100CL, Vitalmax 2100, Vitalmax 2200, Vitalmax 4000, Vitalmax 4000 Modular, Vitalmax 4000CL, Vitalmax 4100, Vitalmax 4100CL, Vitalmax 800 Plus |
| HPs | M3921A A1, M3923A A1, M3925A A1, M3927A A3, M3929A A3, iE33 xMatrix Ultrassom CX50 |
| Smithss Medical > BCI | 3101, 3404, 6100, 6200, 9100, 9200, Advisor, Autocorr, Autocorr: Surgivet |
| Spacelab | 500, 600, 67112, 900, 90300, 90303, 90303B, 90400, 90408, 90425, 90428, 90431, 90432, 90600, 90601A, 90602A, 90603A, 90700, 90701, 90721, 90724, AriaTele, Medic 3, Medic 4, Medic 5, Medic 6, PC Bedside, Série 600, Série 900 |
| Strykers > Medtronics > Controle Physios | 1440/R, Lifepak 10, Lifepak 5, Lifepak 6, Lifepak 6S, Lifepak 7, Lifepak 8, Lifepak 9, VSM-1ESF, VSM-2, VSM-2ESF, VSM-3 |
| Venni | VI-1060P |
| Welch Allyn | 1500, Atlas, PIC 30, PIC 40, PIC 50, Propaq 206 EMPSC, Ultra Smart |
| Alfândega | D900, E Series, M Series, PD1200, PD1400, PD1600, PD1700, PD2000, |
Especificações:
|
Lugar de Origem |
Guangdong, China (Continental)
|
Amostra |
Disponível |
|
Cor do cabo |
Cinza Claro |
Certificado |
CE,ISO13485 |
|
OEM/ODM |
Bem-vindo |
Eletrodos
|
4-lead |
|
Material do Cabo |
TPU médico |
Comprimento principal do cabo |
0,9 m |
|
Tipo |
Snap/Clip |
Padrão |
IEC/AHA |
|
Conector & Garfo |
Plug de nylon e pinos revestidos a ouro
|
Garantia |
garantia de 12 meses e 3 meses para substituição |
|
Quantidade mínima |
1pcs |
Embalagem |
1pc/bag, com caixa externa para proteger |
Características:
• Segurança do Paciente
• Conforto do Paciente
• Estruturas de duplo escudo
• Melhora o desempenho anti-interferência
• Garanta o sinal preciso
• Excelente compatibilidade biológica
• Ideal para pacientes adultos e pediátricos
• Livre de látex



Podemos fornecer cabos de ECG de alta qualidade da HP, GE, MEK, Datex, Mindray, Biolight, Nihon Kohden, Siemens, Spacelabs, Kontron, Datascope, etc., com padrão AHA/IEC, se t se precisar de qualquer item, por favor entre em contato comigo! Serei mais do que feliz em fornecer as informações que você deseja.

Embalo e envio
Embalo: Embalado com saco plástico PE transparente, cada saco com 1 unidade, depois colocado na caixa externa
Prazo de Entrega:
1.48 horas para pedido de amostra, 3-7 dias para pedido em grande quantidade.
2. Negociação de produtos personalizados.

Os nossos principais produtos
1. Sensor Spo2, Adaptador Spo2 Cable
2. Cabos ECG, Cabos EKG
3. Cabo IBP, Cabo EEG
4. Ultrassom Sonda
5. NIBP Mangueira$Tubos
6. Temperatura Sonda
7. Sangue Transdutor de pressão
8. Fetal Transdutor
9. Cinto de CTG
Nossa Vantagem
1. Alta qualidade e preço competitivo;
2. Embalagem padrão e entrega pontual;
3.Nós fornecemos OEM/ODM serviço;
4.Pedido de Amostra e Pedido Pequeno são aceitáveis;
5.Somos um fabricante profissional na China.
6.Temos certificado CE e ISO
7. Os métodos de entrega: DHL, EMS, UPS ou Fedex (rápido e mais seguro)
8. Todos os produtos têm garantia de um ano e garantia de três meses para troca
ONLINE