Compatibile con Draegers Vitalert 2000/ Vitalert 3000 Cavo Paziente ECG a 4 condutture Clip IEC Cavo ECG/EKG per Monitoraggio del Paziente
Descrizione
Compatibile con Draegers Vitalert 2000/ Vitalert 3000 cavo paziente ECG a 4 conduttori con clip IEC per monitoraggio del paziente
Compatibilità:
| Produttore | Modello |
|---|---|
| AAMI | TUTTI |
| ATL | 800, 800 Plus, 800Plus, Apogee, CX ATL Ultrasound, CX200, CX400, HDI 9/200, HDI 9/2000, Interspec Cardiologia XL, Mark IV, Mark Vii, Ultramark 4/5/7/9 |
| Abbot | EX-50, Lifecare 5100, Lifecare 5200 |
| Avanzato | PM-1000, PM-1000EX |
| American Optical | 26125, 33167, 5260, 5330, Pulsar 4 |
| Carewell | CPM-8000 |
| Conmed | 90347 |
| Contec | CMS 6000, CMS 6800, CMS 7000, CMS 8000, CMS 9000 |
| Nelcorr | C-LOCK, N-1000, N-200, N-250, NPB-3900, NPB-4000 |
| Criticare | 1100, 2200, 504US, 504USP, 506, 507, 507E, 507ELC2, 507S, 508, 602-4B, 602-4USP, 8100, 8100E, 8100EP, 8100EP1, Poet 2, Scholar, nCompass, nGenuity 8100E |
| Stile DIN | TUTTI |
| DRE | Waveline EZ MAX, Waveline Pro |
| Datex Ohmeda | enGuard CM5 |
| Digicare | LW600 |
| Dixtal | DX 2022, DX 2515 |
| Draegers > Air Shields | HRRM-71-1, HRRM-71-2, II, III, Porta-Fib I, Porta-Fib II, Porta-Fib III, System 5 (Nuovo), System 6 (Neonatale) |
| Draegers | Vitalert 2000, Vitalert 3000 |
| Edan | M50, M8, M80, M8A, M8B, M9, M9A |
| GE | 556 |
| GE Dinamap | serie 8100T, Serie 8700, 8700/9700, Serie 9700, MPS Select, Pro 1000 |
| Goldway | G30, G40, UT4000A, UT4000Apro, UT4000B, UT4000C, UT4000F, UT4000F Pro, UT4800, UT6000A, UT6000F |
| Guthan | 1000 |
| Infiniums | Infitron II, Omni, Omni II |
| Interspec (Irex) (JandJ) | Cardiologia XL, Mark IV, Mark Vii, Ultramark 4, Ultramark 4 Plus, Ultramark 5, Ultramark 7, Ultramark 9 |
| Invivo | 101, 102, 200, 360SL, 450SL, 521A, Escort 100, Escort 101, Escort 102, Escort 200, Escort 300, M12, Millennia 3500, PortaPak 1000, PortaPak 80, PortaPak 90, PortaPak 90/1000, Prism |
| Ivy Biomedical | 101, 101 (prima del 1989), 3000, 402, 405T, 700, 7600, 7800, Cardiac Trigger Monitor 3150 |
| LSI | 261, LS5 |
| Mediana | YM6000 |
| Midmark > Cardell | 9403V, Serie 9405, Serie 9500, MAX-12 Duo HD, Max-1 |
| Mindray > Datascope | DPM4, DPM5, MEC 1000, MEC 1200, MEC 200, MEC 2000, MEC-1200Vet, PM 7000, PM 8000, PM 9000 |
| Nihon Kohden | 7102A, BSM-7102A, BSM-7300A, BSM-8108A, BSM-8301A, BSM-8302A, BSM-8500A, BSM-8502A, BSM-8800A, Life Scope 12, Life Scope 6, Life Scope 7, Life Scope 8, Life Scope 9, MU-831RA, OEC-6102A (s/n>20156), OEC-6105A (s/n>20226), OEC-7102A, OEC-8108A, TEC 5531E, TEC-5200A (s/n>20421), TEC-7100A, TEC-7200A, TEC-7300A |
| Novametrix | 902, 903, 910, Life Defense 1 |
| Omron > Colin | BP-308, BP-408, CBM3000, M20, M30, MS20 |
| PPG | Guardian 1001, N1001 |
| PaceTech | 2100, 2200, 4000, 4100, MiniMax 4000CL, Minipack 300, Minipack 3000, Minipack 3000/3100, Minipack 3100, Modular/4100CL, Vitalmax 2100, Vitalmax 2200, Vitalmax 4000, Vitalmax 4000 Modular, Vitalmax 4000CL, Vitalmax 4100, Vitalmax 4100CL, Vitalmax 800 Plus |
| HPs | M3921A A1, M3923A A1, M3925A A1, M3927A A3, M3929A A3, iE33 xMatrix Ultrasound CX50 |
| Smithss Medical > BCI | 3101, 3404, 6100, 6200, 9100, 9200, Consigliere, Autocorr, Autocorr: Surgivet |
| Spacelab | 500, 600, 67112, 900, 90300, 90303, 90303B, 90400, 90408, 90425, 90428, 90431, 90432, 90600, 90601A, 90602A, 90603A, 90700, 90701, 90721, 90724, AriaTele, Medic 3, Medic 4, Medic 5, Medic 6, PC Bedside, Serie 600, Serie 900 |
| Strykers > Medtronics > Physios Control | 1440/R, Lifepak 10, Lifepak 5, Lifepak 6, Lifepak 6S, Lifepak 7, Lifepak 8, Lifepak 9, VSM-1ESF, VSM-2, VSM-2ESF, VSM-3 |
| Venni | VI-1060P |
| Welch Allyn | 1500, Atlas, PIC 30, PIC 40, PIC 50, Propaq 206 EMPSC, Ultra Smart |
| Dogana | D900, E Series, M Series, PD1200, PD1400, PD1600, PD1700, PD2000, |
Specifiche:
|
Luogo di origine |
Guangdong, Cina (continente)
|
Campione |
Disponibile |
|
Colore del cavo |
Grigio chiaro |
Certificato |
CE,ISO13485 |
|
OEM/ODM |
Benvenuto |
Elettrodi
|
cavo a 4 conduttori |
|
Materiale del Cavo |
Medico TPU |
Lunghezza principale del cavo |
0.9m |
|
TIPO |
Inserimento/Serratura |
Standard |
IEC/AHA |
|
Connettore & Yoke |
Inserimento in nylon e pin dorati
|
Garanzia |
garanzia di 12 mesi e 3 mesi per il cambio |
|
MOQ |
1pz |
Imballaggio |
1pezzi/busta, con scatola esterna per proteggere |
Caratteristiche:
• Sicurezza del paziente
• Comfort del paziente
• Strutture a doppia protezione
• Migliorare le prestazioni antiperturbazione
• Garantire la precisione del segnale
• Eccellente biocompatibilità
• Ideale per pazienti adulti e pediatrici
• Senza lattice



Possiamo fornire cavi ECG di alta qualità per HP, GE, MEK, Datex, Mindray, Biolight, Nihon Kohden, Siemens, Spacelabs, Kontron, Datascope, ecc. secondo lo standard AHA/IEC, se t se hai bisogno di qualunque articolo, contattami! Sarà un piacere fornire le informazioni che desideri.

Imballaggio e Spedizione
Imballaggio: Avvolgere con sacchetti di plastica PE trasparente, un pezzo per ogni sacchetto, poi mettere nella scatola esterna
Tempo di Consegna:
1.48 ore per l'ordine di campione, 3-7 giorni per l'ordine in grande quantità.
2. Negoziazione di prodotti personalizzati.

I nostri prodotti principali
1. Sensore Spo2, Adattatore Spo2 Cavo
2. Cavo ECG, Cavo EKG
3. Cavo IBP, Cavo EEG
4. Ecografia Sonda
5. NIBP Manica$Tubi
6. Temperatura Sonda
7. Pressione Trasduttore di pressione
8. Feto Trasduttore
9. Cintura CTG
Il Nostro Vantaggio
1. Alta qualità e prezzo competitivo;
2. Imballaggio standard e consegna tempestiva;
3.Forniamo OEM/ODM servizio;
4.L'ordine di campioni e gli ordini piccoli sono accettabili;
5.Siamo un produttore professionista in Cina.
6.Possediamo il certificato CE e ISO
7.I metodi di consegna: DHL, EMS, UPS o Fedex (veloci e più sicuri)
8.Tutti i prodotti hanno una garanzia di un anno e una garanzia di tre mesi per il cambio
ONLINE