Compatibile per Nellcorrsss N-600x Sensore SpO2 Schedabile NPB-3940 Neonato/adulto DB9 Plug Sensore SpO2 Schedabile
Descrizione
Compatibile con Nellcorsss N-600x sensore SpO2 monouso NPB-3940 Neonato/adulto Sonda spo2 usa e getta con connettore DB9
1. Descrizione del prodotto:
| Produttore | OEM Part # |
|---|---|
| Conmed | 2314 |
| Covidiens > Nellcorss | MAX-N , MAX-N-I |
| Draegers | MX50068 |
| GE Healthcare > Marquette | 70124032 |
| Mindray > Datascope | 0010-10-12205 |
| Sage | DP06X-09M |
| Strykers > Medtronics > Physios Control | 11996-000117 |
Compatibilità:
| Produttore | Modello |
|---|---|
| Baxter |
Explorer, Monarch
|
| Biolight |
M9500, Q Series, Q3, Q5, Q7
|
| Biosys |
BPM-200, SENTRY
|
| CAS Med |
511
|
| Covidiens > Nellcorss |
N-10, N-180, N-190, N-20, N-30, N-560, N-600, N-600x, N-65, N-85, NPB-190, NPB-195, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, PM100N, PM10N, Sensori che hanno la Tecnologia OxiMax di Nellcor e 9 pin
|
| Criticare |
506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3
|
| DRE |
ASM 5000, Waveline, Waveline Plus
|
| Digicare |
LW600
|
| Draegers |
Infinity Delta, Infinity Delta XL, Infinity Kappa, Narkomed 6400
|
| Fukuda Denshi |
Dynascope DS-7100, Dynascope DS-8100, LX-7230N
|
| GE Healthcare > Critikon > Dinamap |
B105, B125, Carescape B650, Carescape V100, Compact DINAMAP MPS, E-NSAT, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro Series V2, ProCare 200, ProCare 400, ProCare Auscultatorio 400
|
| GE Healthcare > Marquette |
Dash 2500, Dash 3000, Dash 4000, Dash 5000, Modulo PDM, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500
|
| Goldway |
Vet 420A, Vet 600A
|
| Medtronics > Covidiens |
Capnostream 35 (PM35MN)
|
| Midmark > Cardell |
serie 9403, 9405, 9500, 9500HD, MAX-12 Duo HD
|
| Mindray > Datascope |
Accutorr Plus, BeneView T1, BeneVision N1, DPM5, DPM6, DPM7, Duo, Expert, Passport, Passport 12, Passport 2, Passport 8, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V-Series, VS 8, VS 8A, VS 8C, VS 9, VS 9A, VS 9C, ePM 10M, ePM 12M, iMEC 10, iMEC 12, iMEC 15, iMEC 15S, iMEC 5, iMEC 6, iMEC 7, iMEC 8, iMEC Series, iPM-9800
|
| Mortara |
Surveyor S12/S19
|
| Omron > Colin |
BP-S510, T105NXM
|
| Philipss |
FM20, FM30, Heartstream XL, IntelliVue, IntelliVue FAST-SpO2, IntelliVue MP2, IntelliVue MP70, IntelliVue MX450, M1020B, M2601A, M3000A, M3001A, M3001A A02, M3001A A02C06, M3001A A02C12, M3001A A02C18, M3001A A04, M3001A A04C06, M3001A A04C12, M3001A A04C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A, M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3
|
| Smiths Medical > BCI |
3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, Advisor, Autocorr, Mini Torr, Mini Torr Plus
|
| Spacelabs |
Ultraview SL, Ultraview SL 2700
|
| Stryker > Medtronic > Physio Control |
Lifepak 12, Lifepak 15
|
| Welch Allyn |
1500, 42NT0-E1 LXi, 52N Series, 53N Series, 64N Series, 65N Series, 67N Series, 68N Series, 71WT-B Connex Spot, 73C Series, 74C Series, 75CE-B, 75CT-B, 75CX-B, 901058, Tutti, Atlas (Nellcor SpO2), Atlas 6200 Series, Connex 6000 series, Encore 202EL, Propaq 244, Propaq CS, Propaq LT, Spot Vital Signs 42MOB, Spot Vital Signs 42NOB, Spot Vital Signs 42NTB-E1
|
| Dogana |
E Series, M Series, R Series
|
|
Marca compatibile |
Nelcor |
||
|
Tipo di sensore |
Adulto, Pediatrico, Infante, Neonato; Schiuma Blu Non Adesiva, Adesivo Non Tessuto 3M, Adesivo Schiuma Bianca 3M. |
||
|
Materiale del Cavo |
giacca in PVC bianco, 3,2 mm di diametro |
Connettore sensori |
Adattatore in plastica con pinne dorature |
|
LED |
660nm\/905nm\/940nm |
Fotodetettore |
4mm² /8mm² (dimensione) |
|
Lunghezza del cavo |
0.9m |
Imballaggio |
1pz in una busta zip |
2. Prodotto T ecnico P di cui: :
|
LED |
Rosso |
660nm normale |
|
Infrarossi |
880/905/940nm normale |
|
|
Intervallo di Testo |
Saturazione di Ossigeno (%SpO2) |
0% a 100% |
|
Frequenza Cardiaca (bpm) |
30 a 245 |
|
|
Precision |
SpO2 |
±1%(90~100%) |
|
±2%(80~90%) |
||
|
±3%(inferiore al 70%) |
||
|
Tasso di polso |
±2bpm(30-250bpm) |
|
|
Ambiente di conservazione e trasporto |
-10℃~+40℃ |
|
|
Temperatura di funzionamento |
±5℃~+40℃ |
|
|
Umidità di funzionamento/immagazzinamento/trasporto |
0%-80% |
|
|
Pressione iperbarica |
86kPa-106kPa |
|
3. Caremed Immagine del prodotto s :



4. Caremed Rapporto di Test del Prodotto :

5. Più prodotti principali di Caremed:
A. - Sì. Sensore SpO2, Estensione SpO2 ;
Cavo Holter ECG;
Cavo ECG/EKG, Cavo di Connessione ECG/EKG, Elettrodi ECG;
Trasduzione IBP, Cavo IBP;
Manica NIBP, Tubo NIBP;
Sonda Termica, Trasduzione Feticale, Cintura CTG;
Trasduzione a Ultrasuoni, Riparazione Sonda a Ultrasuoni.
Tutte le marche compatibili disponibili per quanto sopra. (Contatta ora, risparmia di più)

ONLINE